TCH seal
Tarangnan Community Hospital — Clinical Laboratory

Segregate Waste at the Point of Generation

Four streams only. Segregate where the waste is produced — never mix streams (DOH Healthcare Waste Management Manual; RA 6969).
INFOGRAPHIC IG-05
Source: LAB-QM-IC-001 §5.4
Version V0 — DRAFT
Yellow
Infectious / Biohazard
Heavy-duty yellow plastic liner
Put inBlood-soaked gauze · contaminated gloves · used pipette tips · specimen cups When ¾ fullSeal, tie the neck securely, attach a biohazard tag with date and section.
Red or Yellow Box
Sharps Waste
Rigid, puncture-proof container — red, or yellow clearly labeled “Biohazard Sharps”
Put inNeedles · vacutainer needles · lancets · glass slides · broken glass When ¾ fullSeal permanently. Never recap, bend, or shear needles.
Black
General (Non-Infectious)
Black plastic liner
Put inOffice paper · packaging boxes · clean plastic wrappers DisposalMunicipal collection. Do not mix with biohazard waste.
Carboy
Liquid Chemical / Effluent
Rigid heavy-duty carboy / container
Put inHematology / chemistry analyzer liquid effluent · chemical reagents HandlingNeutralize per protocol; store in the dedicated holding area for authorized treatment.

Sharps rules — LAB-QM-SAF-001 §5.4

Pathologic waste, transport & disposal — §5.4